You are currently viewing DLSS 5 increases RTX 5090 power consumption: test measures 91.7 °C

DLSS 5 increases RTX 5090 power consumption: test measures 91.7 °C

  • Post author:
  • Post last modified:
  • Post category:Graphics / News
  • Reading time:10 mins read

A new technical test shows that DLSS 5 significantly increases the power consumption of the RTX 5090 under heavy load. In Cyberpunk 2077, a GeForce RTX 5090 Founders Edition reached 91.7 °C at the 12V-2×6 connector with Neural Rendering enabled, compared to 80.9 °C under the same conditions without DLSS 5.

QuasarZone conducted the test at 3840 × 2160, Ultra preset, and DLSS in Quality mode for 20 minutes. In addition, the lab maintained the ambient temperature at 27.5 °C ±0.5 °C and measured power consumption, temperature, and current using HWiNFO, NVIDIA PCAT, and thermography.

The most interesting result appears in power consumption. According to PCAT, the total average power of the RTX 5090 rose from 527.3 W to 593.9 W. At the same time, the 16-pin connector alone went from 516.5 W to 582.7 W. Therefore, practically the entire average increase observed on the board also appeared in the 12V-2×6.

Gráfico comparando a temperatura do conector 12V-2x6 da RTX 5090 e RTX 5080 com DLSS 5 ligado e desligado

At the hottest point measured, the RTX 5090 FE connector went from 80.9 °C to 91.7 °C with DLSS 5. Data: QuasarZone, chart reproduced by 3DNews.

RTX 5090 reaches 91.7 °C on the connector with DLSS 5

The thermal test measured the RTX 5090 Founders Edition connector from both sides.

On the side facing the four signal pins, the maximum temperature went from 80.9 °C without DLSS 5 to 91.7 °C with the technology enabled.

On the latch side, however, the test recorded 77.1 °C without Neural Rendering and 83.4 °C with the feature enabled.

Thus, the largest increase occurred precisely at the point that already had the highest temperature before DLSS 5 was activated.

However, these numbers need context. The test does not show that any RTX 5090 will automatically reach 91.7 °C. It records the behavior of a specific Founders Edition subjected to a defined load, environment, and duration.

Nor is there any evidence in this test that reaching 91.7 °C necessarily means the connector is about to melt.

The result shows something more objective: Neural Rendering simultaneously increased the sustained power and the connector temperature in this configuration.

DLSS 5 added about 66 W of average power consumption to the RTX 5090

The power measurements help explain the thermal difference.

HWiNFO recorded an average power consumption of 509.2 W with DLSS 5 turned off. When QuasarZone enabled Neural Rendering, the average rose to 575.1 W.

This put the RTX 5090 very close to its nominal power limit of 575 W.

On the other hand, the NVIDIA PCAT recorded even higher values because it externally measures the power supplied to the card and also captures short peaks.

According to the PCAT, the total average went from:

527,3 W → 593,9 W

The total peak went from:

582,5 W → 658,0 W

Therefore, the total average increase measured by the PCAT was approximately 66,6 W.

Gráfico do NVIDIA PCAT comparando o consumo total das RTX 5090 e RTX 5080 com DLSS 5 ativado e desativado

The PCAT recorded an average of 593,9 W and a peak of 658 W on the RTX 5090 FE with DLSS 5 enabled. Data: QuasarZone, chart reproduced by 3DNews.

Almost all of the increase appeared in the 16-pin connector

The separate measurement of the 12V-2×6 makes the test particularly interesting.

Without DLSS 5, the PCAT recorded 516.5 W on average through the connector. With Neural Rendering, this average reached 582.7 W.

Thus, the connector started to provide approximately 66.2 W of additional sustained power in the tested scenario.

The peaks also increased. The maximum value observed on the 12V-2×6 went from 571.7 W to 646.7 W.

Gráfico mostrando potência média e de pico fornecida pelo conector 12V-2x6 da RTX 5090 e RTX 5080

On the RTX 5090's 12V-2×6 connector, the average reached 582.7 W and the peak reached 646.7 W with DLSS 5. Data: QuasarZone, chart reproduced by 3DNews.

This helps explain why just looking at "GPU Usage = 100%" doesn't tell the whole story.

Two different workloads can keep the GPU close to 100% and still demand different levels of power, current, and frequency.

In this test, Neural Rendering maintained a heavy enough load to push the RTX 5090 very close to its power limit for prolonged periods.

Check out all the RTX 5090 measurements with DLSS 5

Measurement DLSS 5 off DLSS 5 enabled
HWiNFO — average power 509.2 W 575.1 W
PCAT — total average power 527.3 W 593.9 W
PCAT — total peak 582.5 W 658.0 W
12V-2×6 — average power 516.5 W 582.7 W
12V-2×6 — peak 571.7 W 646.7 W
Connector — hottest point 80.9 °C 91.7 °C
GPU — average temperature 79.4 °C 83.0 °C
GPU — peak 82.3 °C 86.3 °C

The table also shows an important difference between the GPU temperature and the connector temperature.

While the hottest point of the 12V-2×6 increased by 10.8 °C, the average GPU temperature rose from 79.4 °C to 83 °C.

Therefore, the connector reached a higher temperature than the graphics processor itself during this test.

RTX 5080 showed much less extreme behavior

QuasarZone repeated part of the analysis with a GeForce RTX 5080 Founders Edition.

In this case, HWiNFO recorded an increase from 298.2 W to 350.3 W of average power after enabling DLSS 5.

However, the connector temperatures remained well below those observed on the RTX 5090.

On the signal contacts side, the RTX 5080 went from 47.6 °C to 48.6 °C. Meanwhile, on the latch side, the measurement went from 45.8 °C to 52.2 °C.

Thus, the test provides an important warning against generalizations.

The fact that the RTX 5090 reached 91.7 °C does not mean that every GeForce RTX 50 exhibits the same behavior with DLSS 5.

The RTX 5090 operates with a much higher power budget. According to NVIDIA's official specification, the Founders Edition has a Total Graphics Power of 575 W, whereas the RTX 5080 operates in a considerably lower range.

Test with ASUS ROG Astral measures current on each contact

QuasarZone also used an ASUS ROG Astral RTX 5090 to analyze the individual current across the six power contacts.

To make the comparison closer to the Founders Edition, the lab capped the card at 575 W.

Without DLSS 5, the contacts carried between 6.94 A and 7.47 A.

With Neural Rendering, the range rose to 7.83 A to 8.51 A.

All six contacts remained below the 9.2 A reference value used in the analysis.

However, the higher load reduced the available margin and increased the current in all contacts.

10.1 A scenario was a simulation, not a real failure

The test also presents a hypothetical calculation that needs to be separated from the physical measurements.

The authors simulated what would happen if one of the contacts stopped conducting due to poor contact or wear.

In this theoretical scenario, the remaining contacts would need to absorb the lost current.

Without DLSS 5, the most heavily loaded contact would reach approximately 8.9 A.

With DLSS 5, the calculation brings this value to approximately 10.1 A.

However, this did not happen physically during the test.

Therefore, the figure of 10.1 A does not prove that DLSS 5 causes contact failure. It only shows how a higher electrical load could alter the distribution in a hypothetical situation where a contact already presented an issue.

The test does not prove that DLSS 5 melts RTX 5090 connectors

Previous reports have already associated DLSS 5 tests on the RTX 5090 with damaged connectors. However, these episodes alone do not establish a causal relationship.

Issues with high-power connectors have also appeared in other workloads and situations that did not involve DLSS 5.

Furthermore, the new QuasarZone test did not produce a melted connector.

What the instruments measured directly was something else: more power, more current, and higher temperature when Neural Rendering came into play.

Thus, it would be incorrect to turn 91.7 °C into a claim that “DLSS 5 melts the RTX 5090”.

On the other hand, it would also be incorrect to ignore the measured load increase.

The technology added approximately 66 W of average power consumption to the card in this scenario and kept the 12V-2×6 supplying over 580 W on average during the test.

Why does Neural Rendering increase the load so much?

DLSS 5 adds a heavy neural step to the graphics pipeline.

In addition to rendering the game and running the other configured technologies, the GPU needs to evaluate the Neural Rendering model.

Therefore, a card that still has power and processing headroom can raise clocks, compute unit utilization, and power consumption to complete the additional work.

In the tested RTX 5090 FE, the result pushed the card practically to its nominal limit.

This also helps explain why the cost of DLSS 5 should not be measured in FPS alone.

To analyze the technology in greater depth, power and frametime metrics provide information that the frame counter and utilization percentage do not show on their own.

Multipass does not mean consumption multiplied by the number of passes

The results are also relevant for experiments that run Neural Rendering multiple times over the same frame.

However, five passes do not automatically mean five times the electrical consumption. Likewise, ten passes do not mean ten times more watts.

The GPU has power, voltage, temperature, and frequency limits.

When the load increases, the card adjusts its clocks and other variables to remain within these limits.

Therefore, the main point to observe in Multipass is how long the GPU stays close to its power limit.

A heavy sequence may not continuously increase the peak wattage, but it can sustain the card near that ceiling for a longer time.

Is it worth monitoring power during DLSS 5 tests?

Yes. The new test shows that average sustained power adds important information to Neural Rendering analyses.

A testing methodology can track:

  • FPS;
  • frametime;
  • GPU Usage;
  • GPU temperature;
  • average GPU power;
  • power spikes;
  • clock speed;
  • used VRAM.

For ordinary users, there is no need to deliberately replicate an extreme connector test.

Monitoring tools already allow observing the GPU's electrical behavior during a normal gaming session.

Furthermore, manually raising the power limit is not necessary to find out if a certain DLSS 5 configuration increases the sustained load.

The results of the RTX 5090 cannot be directly transferred to an RTX 5060 Ti

Another important distinction involves the other GPUs in the family.

The 91.7 °C test uses an RTX 5090 Founders Edition with power consumption close to 600 W.

An RTX 5060 Ti operates in a very different power class. Therefore, there is no basis to claim that it will present similar temperatures at the connector or the same absolute increase in consumption.

The same applies to the RTX 5070, RTX 5080, and modified cards designed to run Feature 18 outside of the officially intended path.

Testing of the RTX 5080 itself reinforces this difference: although power also increased with Neural Rendering, the connector remained much cooler.

What does this test actually demonstrate?

The main contribution of the analysis lies in the separation between graphical load and power delivery.

QuasarZone did not just observe GPU utilization. The lab directly measured how much the card received, how much passed through the connector, and how the temperature responded after 20 minutes.

On the tested RTX 5090 Founders Edition, DLSS 5 pushed the total average power consumption measured by the PCAT from 527.3 W to 593.9 W.

At the same time, the 12V-2×6 went from an average of 516.5 W to 582.7 W, while the hottest point temperature increased from 80.9 °C to 91.7 °C.

This provides instrumental evidence that Neural Rendering can substantially increase the sustained electrical load on an RTX 5090 already operating near its limits.

However, the test does not demonstrate that DLSS 5 alone causes connector failures, nor does it allow generalizing the 91.7 °C to the entire RTX 50 family.

The next step will be to verify whether other RTX 5090 cards, cables, power supplies, and card models exhibit similar behavior under the same methodology.

Sources: VideoCardz — QuasarZone test data | PC Master Race Latinoamérica — table and measurement analysis | 3DNews — reproduction of QuasarZone measurements and charts | NVIDIA — official GeForce RTX 5090 specifications.

This Post Has 2 Comments

Comments are closed.